Philips HF-P 1 14-35 TL5 HE III 220-240V 50/60Hz

Quantity | Unit price | You save |
---|---|---|
From 10 | €13.80 * | 5.15 % |
Specifications | |
General Information | |
Application Code: | III |
Type Version: | IDC |
Lamp Type: | TL5 HE |
Number of Lamps: | 1 piece/unit |
Number of Products on MCB (16A Type B) (Nom): | 28 |
Automatic Restart: | Yes |
Operating and Electrical | |
Input Voltage: | 220 to 240 V |
Input Frequency: | 50 to 60 Hz |
Operating Frequency (Nom): | 45 kHz |
Ignition Method: | Programmed Start |
Crestfactor (Max): | 1.7 |
Power Factor 100% Load (Nom): | 0.99 |
Ignition Time (Max): | 0.9 s |
Mains Voltage Performance (AC): | -8%-+6% |
Mains Voltage Safety (AC): | -10%-+10% |
Earth Leakage Current (Nom): | 0.5 mA |
Inrush Current Width: | 0.25 ms |
Constant Wattage Deviation: | -2%/+2% |
Ballast Factor (Nom): | 1.07 |
Power Losses (Nom): | 2.0-3.0 W |
Inrush Current Peak (Max): | 24 A |
Wiring | |
Connector Type Input Terminals: | WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Cable Capacity Output Wires Mutual (Nom): | 200 pF |
Connector Type Output Terminals: | WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Cable Length Hot Wiring: | 0.75 m |
Wire Striplength: | 8.0-9.0 mm |
Dual Fixture Master/Slave: | Not applicable [ Master/Slave oper. not applicable] |
Input Terminal Cross Section: | 0.50-1.00 mm² |
Output Terminal Cross Section: | 0.50-1.00 mm² |
Cable Capacity Output Wires to Earth (Nom): | 200 pF |
System characteristics | |
Rated Ballast-Lamp Power: | 14-35 W |
Rated Lamp Power on TL5 HE: | 14/35 W |
System Power on TL5 HE: | 16.0/39.5 W |
Lamp Power on TL5 HE: | 14.0/36.5 W |
Power Loss on TL5 HE: | 2.0/3.0 W |
Temperature | |
T-Ambient (Max): | 60 °C |
T-Ambient (Min): | -25 °C |
T-Storage (Max): | 80 °C |
T-Storage (Min): | -40 °C |
T-Case Lifetime (Nom): | 80 °C |
T-Case Maximum (Max): | 80 °C |
T-Ignition (Max): | 50 °C |
T-Ignition (Min): | -25 °C |
Mechanical and Housing | |
Housing: | L360x30x22 |
Emergency Operation | |
Nominal Light Output After 60 Seconds: | 100% of EBLF |
Battery Voltage Lamp Ignition: | 186-275 V |
Normal Operating Voltage (DC): | 220-240 V |
Battery Voltage Lamp Operation: | 186-275 |
Battery Voltage Guaranteed Operation: | 176-275 V |
Battery Voltage Guaranteed Ignition: | 186-275 V |
Emergency Ballast Lumen Factor (EBLF) (Nom): | 0.7 % |
Nominal Light Output After 5 Seconds: | 50% of EBLF |
Approval and Application | |
Energy Efficiency Index: | A2 BAT |
IP Classification: | IP 20 [ Ingress Protection 20] |
EMI 9 kHz ... 30 MHz: | EN55015 |
EMI 30 MHz ... 1000 MHz: | - |
Safety Standard: | IEC 61347-2-3 |
Performance Standard: | IEC 60929 |
Quality Standard: | ISO 9000:2000 |
Environmental Standard: | ISO 14001 |
Harmonic Current Emission Standard: | IEC 61000-3-2 |
EMC Immunity Standard: | IEC 61547 |
Vibration Standard: | IEC68-2-6 F c |
Bumps Standard: | IEC 68-2-29 Eb |
Humidity Standard: | EN 61347-2-3 clause 11 |
Approval Marks: | CE marking, ENEC certificate, VDE-EMV certificate |
Temperature Marking: | Yes |
Emergency Standard: | IEC 60598-2-22 |
Hum And Noise Level: | < 30 dB(A) |
Product Data | |
Net Weight (Piece): | 0.220 kg |



Mon-Fri: | 08:00 am – 05:00 pm |